All IDENTIFICATION will be in Accordance
with MIL-W-5088L and AS50881A
Section 3.9
Each wire and cable shall be marked with an identification
code on the jacket. Hot Stamp marking of wire and cable shall not be used
unless other marking methods are not compatible with wire or cable insulation
Section 3.9.3.1
The wire identification code shall be printed to read horizontally
from left to right or vertically from top to bottom
Section 3.9.3.2
The characters shall be legible and permanent and the method
of identification shall not impair the characteristics of the wiring
Section 3.9.3.3
Wiring shall be identified, throughout its length, at intervals
not longer than three (3) inches, as measured from the end of a mark to
the beginning of the next mark
Section 3.9.3.3.1
Unjacketed conductors: Example - (M27500-22SB2U00). The marker
shall be Mil-I-23053 heat shrinkable sleeve within three (3) inches from
their termination and not greater than three (3) feet intervals upon the
entire length of the conductor
Method of ID
Non contact wire identification in the form of ink jet shall
be used on both jacketed single conductor and twisted pair conductors
Packaging:
As per your instructions: Standard is each wire number/length on separate spools. Each
spool with label to include: wire segment #, wire type, length, assembly
no.